이미지는 예시일 수 있습니다.
제품 세부사항은 사양을 확인하세요.
MAX836EUS+TG002

MAX836EUS+TG002

Product Overview

  • Category: Integrated Circuit (IC)
  • Use: Voltage Monitor and Reset Circuit
  • Characteristics:
    • Monitors the voltage level of a power supply and generates a reset signal when the voltage falls below a specified threshold.
    • Provides a reliable way to ensure proper system operation by resetting the microcontroller or other digital logic devices during power-up, power-down, or brownout conditions.
  • Package: SOT-143
  • Essence: Voltage monitoring and reset functionality in a compact package.
  • Packaging/Quantity: Tape and Reel, 3000 units per reel.

Specifications

  • Supply Voltage Range: 1.2V to 5.5V
  • Threshold Voltage Options: 2.5V, 3.08V, 4.63V
  • Reset Timeout Period: Adjustable from 1ms to 1600ms
  • Operating Temperature Range: -40°C to +85°C

Pin Configuration

The MAX836EUS+TG002 IC has the following pin configuration:

```


| | --| VCC |-- --| RESET |-- --| GND |-- |_______| ```

Functional Features

  • Monitors the voltage level continuously.
  • Generates a reset signal when the voltage falls below the set threshold.
  • Adjustable reset timeout period allows customization for specific applications.
  • Low quiescent current consumption.
  • Built-in glitch immunity ensures reliable operation.

Advantages

  • Compact package size enables space-saving designs.
  • Wide supply voltage range accommodates various power supply configurations.
  • Adjustable reset timeout period provides flexibility for different system requirements.
  • Low power consumption prolongs battery life in portable applications.
  • Glitch immunity enhances system reliability.

Disadvantages

  • Limited threshold voltage options may not cover all voltage monitoring scenarios.
  • Lack of built-in hysteresis may result in potential oscillations near the threshold voltage.

Working Principles

The MAX836EUS+TG002 operates by comparing the supply voltage with a preset threshold voltage. When the supply voltage falls below the threshold, the internal circuit generates a reset signal, which can be used to reset the microcontroller or other digital logic devices. The reset timeout period determines how long the reset signal remains active after the supply voltage returns above the threshold.

Detailed Application Field Plans

The MAX836EUS+TG002 is commonly used in various applications where reliable voltage monitoring and reset functionality are required. Some typical application fields include:

  1. Embedded Systems: Ensuring proper initialization and operation of microcontrollers, DSPs, and FPGAs.
  2. Industrial Control Systems: Preventing data corruption and ensuring system integrity during power fluctuations.
  3. Automotive Electronics: Resetting critical components during voltage transients to avoid malfunctions.
  4. Medical Devices: Providing a fail-safe mechanism for medical equipment that requires stable power supply.
  5. Consumer Electronics: Protecting sensitive digital circuits from voltage variations and ensuring reliable operation.

Detailed and Complete Alternative Models

  1. MAX809: Voltage monitor and reset circuit with fixed threshold options and adjustable reset timeout period.
  2. ADM708: Supervisory circuit with adjustable threshold voltage and reset timeout period.
  3. TPS3808: Precision voltage supervisor with programmable threshold voltage and watchdog timer.

These alternative models offer similar functionality to the MAX836EUS+TG002 and can be considered based on specific requirements and design constraints.

Word count: 511 words

기술 솔루션에 MAX836EUS+TG002 적용과 관련된 10가지 일반적인 질문과 답변을 나열하세요.

Sure! Here are 10 common questions and answers related to the application of MAX836EUS+TG002 in technical solutions:

  1. Q: What is the MAX836EUS+TG002? A: The MAX836EUS+TG002 is a voltage supervisor IC that monitors the power supply voltage and provides a reset signal when the voltage falls below a specified threshold.

  2. Q: What is the operating voltage range of MAX836EUS+TG002? A: The operating voltage range of MAX836EUS+TG002 is typically between 1.6V and 5.5V.

  3. Q: How does MAX836EUS+TG002 help in technical solutions? A: MAX836EUS+TG002 ensures proper system initialization by monitoring the power supply voltage and generating a reset signal to prevent erratic behavior during power-up or brownout conditions.

  4. Q: Can I adjust the threshold voltage of MAX836EUS+TG002? A: No, the threshold voltage of MAX836EUS+TG002 is fixed at a specific value.

  5. Q: What is the typical reset timeout period of MAX836EUS+TG002? A: The typical reset timeout period of MAX836EUS+TG002 is around 140ms.

  6. Q: Is MAX836EUS+TG002 suitable for battery-powered applications? A: Yes, MAX836EUS+TG002 is suitable for battery-powered applications as it operates within a wide voltage range and consumes low quiescent current.

  7. Q: Can I use MAX836EUS+TG002 with microcontrollers or other digital devices? A: Yes, MAX836EUS+TG002 can be used with microcontrollers, ASICs, FPGAs, and other digital devices to ensure reliable power-on reset functionality.

  8. Q: Does MAX836EUS+TG002 have any built-in protection features? A: Yes, MAX836EUS+TG002 includes features like reverse battery protection and a power-fail comparator to enhance system reliability.

  9. Q: What is the package type of MAX836EUS+TG002? A: MAX836EUS+TG002 is available in a small SOT-143 package.

  10. Q: Can I use MAX836EUS+TG002 in automotive applications? A: Yes, MAX836EUS+TG002 is suitable for automotive applications as it meets the necessary requirements for temperature range, voltage range, and reliability.

Please note that these answers are general and may vary depending on the specific datasheet and application requirements.