이미지는 예시일 수 있습니다.
제품 세부사항은 사양을 확인하세요.
MCP130-270I/SN
Product Overview
Category
MCP130-270I/SN belongs to the category of integrated circuits (ICs).
Use
This product is commonly used in electronic devices for voltage monitoring and reset functions.
Characteristics
- Voltage monitoring: MCP130-270I/SN is designed to monitor the supply voltage and provide a reset signal when it falls below a certain threshold.
- Reset function: It ensures that the microcontroller or other digital circuitry starts in a known state after power-up or brownout conditions.
- Package: The MCP130-270I/SN comes in an industry-standard 8-pin small outline package (SN).
- Essence: This IC is essential for maintaining stable operation and preventing data corruption in various electronic systems.
- Packaging/Quantity: The MCP130-270I/SN is typically packaged in reels, with 2500 units per reel.
Specifications
- Supply Voltage Range: 1.6V to 5.5V
- Threshold Voltage Options: 2.63V, 2.93V, 3.08V, 4.38V, 4.63V, 4.88V
- Operating Temperature Range: -40°C to +85°C
- Quiescent Current: 10µA (typical)
- Reset Timeout Period: 140ms (typical)
Detailed Pin Configuration
The MCP130-270I/SN has the following pin configuration:
- VDD: Supply voltage input
- GND: Ground reference
- MR: Manual reset input
- RESET: Active-low reset output
- VDD: Supply voltage input
- GND: Ground reference
- NC: No connection
- NC: No connection
Functional Features
- Voltage Monitoring: The MCP130-270I/SN continuously monitors the supply voltage and compares it to the preset threshold voltage.
- Reset Generation: When the supply voltage falls below the threshold, the MCP130-270I/SN asserts the reset signal, ensuring a controlled restart of the system.
- Manual Reset: The MR pin allows for manual reset control, overriding the automatic reset function.
Advantages and Disadvantages
Advantages
- Reliable Voltage Monitoring: Ensures stable operation by monitoring the supply voltage.
- Controlled System Restart: Provides a reset signal to bring the system back to a known state after power-up or brownout conditions.
- Manual Reset Capability: Allows for manual control over the reset function.
Disadvantages
- Limited Threshold Options: The available threshold voltage options may not cover all specific application requirements.
- Noisy Environment Sensitivity: High levels of noise in the supply voltage may affect the accuracy of the voltage monitoring.
Working Principles
The MCP130-270I/SN operates by comparing the supply voltage with the preset threshold voltage. When the supply voltage drops below the threshold, the reset output is asserted, indicating a low-voltage condition. This ensures that the connected microcontroller or digital circuitry starts in a known state. The manual reset input allows for an external signal to override the automatic reset function.
Detailed Application Field Plans
The MCP130-270I/SN finds applications in various electronic systems where voltage monitoring and controlled system restart are crucial. Some specific application fields include:
- Embedded Systems: Used in microcontroller-based embedded systems to ensure reliable operation and prevent data corruption during power fluctuations.
- Industrial Automation: Employed in industrial automation equipment to monitor power supply integrity and initiate controlled system restarts when necessary.
- Automotive Electronics: Integrated into automotive electronics to provide voltage monitoring and reset functions, ensuring proper functioning of critical systems.
- Medical Devices: Utilized in medical devices to monitor power supply stability and initiate system resets to prevent data loss or malfunction.
Detailed and Complete Alternative Models
- MCP130-300I/SN: Similar to MCP130-270I/SN but with a higher threshold voltage option of 3.0V.
- MCP130-450I/SN: Offers a higher threshold voltage option of 4.5V, suitable for applications with higher supply voltages.
- MCP130T-315I/TT: Provides an open-drain reset output and a wider operating temperature range (-40°C to +125°C).
These alternative models offer similar functionality with slight variations in threshold voltage options, operating temperature range, and output configuration.
Word count: 550 words
기술 솔루션에 MCP130-270I/SN 적용과 관련된 10가지 일반적인 질문과 답변을 나열하세요.
What is the operating voltage range of MCP130-270I/SN?
- The operating voltage range of MCP130-270I/SN is 2.0V to 6.0V.
What is the typical reset threshold voltage of MCP130-270I/SN?
- The typical reset threshold voltage of MCP130-270I/SN is 2.93V.
Can MCP130-270I/SN be used in automotive applications?
- Yes, MCP130-270I/SN is suitable for automotive applications.
What is the quiescent current consumption of MCP130-270I/SN?
- The quiescent current consumption of MCP130-270I/SN is typically 5µA.
Is MCP130-270I/SN available in a surface-mount package?
- Yes, MCP130-270I/SN is available in a surface-mount package.
What is the temperature range for MCP130-270I/SN?
- MCP130-270I/SN has an operating temperature range of -40°C to 125°C.
Can MCP130-270I/SN be used in battery-powered applications?
- Yes, MCP130-270I/SN is suitable for battery-powered applications.
Does MCP130-270I/SN have a manual reset input?
- No, MCP130-270I/SN does not have a manual reset input.
What is the output type of MCP130-270I/SN?
- MCP130-270I/SN has an active-low, push-pull output.
Is MCP130-270I/SN RoHS compliant?
- Yes, MCP130-270I/SN is RoHS compliant.