이미지는 예시일 수 있습니다.
제품 세부사항은 사양을 확인하세요.
INA118U

INA118U

Product Overview

Category

INA118U belongs to the category of integrated circuits (ICs).

Use

The INA118U is primarily used as a precision instrumentation amplifier. It is designed to amplify small differential signals accurately and reject common-mode noise.

Characteristics

  • High accuracy
  • Low offset voltage
  • Low offset drift
  • High common-mode rejection ratio (CMRR)
  • Wide input voltage range
  • Low power consumption

Package

The INA118U comes in a small outline package (SOIC) with 8 pins.

Essence

The essence of INA118U lies in its ability to provide precise amplification of small differential signals while minimizing common-mode noise interference.

Packaging/Quantity

The INA118U is typically packaged in reels or tubes, with a quantity of 250 units per reel/tube.

Specifications

  • Supply voltage: 2.7V to 36V
  • Input voltage range: ±Vs - 0.1V
  • Gain bandwidth product: 1 MHz
  • Input offset voltage: 50 µV (maximum)
  • Input offset drift: 0.5 µV/°C (maximum)
  • Common-mode rejection ratio: 100 dB (minimum)
  • Operating temperature range: -40°C to +125°C

Pin Configuration

The INA118U has the following pin configuration:

  1. REF (Reference Voltage)
  2. V-
  3. IN-
  4. IN+
  5. V+
  6. RG (Gain Set Resistor)
  7. OUT (Output)
  8. NC (No Connection)

Functional Features

  • Precision amplification of small differential signals
  • High rejection of common-mode noise
  • Adjustable gain through external resistor (RG)
  • Low power consumption for extended battery life
  • Wide operating voltage range for versatile applications

Advantages

  • High accuracy and precision
  • Excellent rejection of common-mode noise
  • Flexible gain adjustment
  • Wide operating voltage range
  • Low power consumption

Disadvantages

  • Limited gain bandwidth product (1 MHz)
  • Requires external gain set resistor for adjustable gain

Working Principles

The INA118U operates based on the principle of differential amplification. It amplifies the difference between the IN+ and IN- inputs while rejecting any common-mode signals. The gain can be adjusted by selecting an appropriate value for the external gain set resistor (RG).

Detailed Application Field Plans

The INA118U finds applications in various fields, including:

  1. Biomedical instrumentation
  2. Industrial process control
  3. Strain gauge amplification
  4. Temperature measurement
  5. Data acquisition systems
  6. Bridge amplification

Detailed and Complete Alternative Models

Some alternative models to INA118U that offer similar functionality include:

  1. AD620
  2. AD8221
  3. MCP6N11
  4. LT1167
  5. MAX4209

These alternatives provide comparable precision amplification and common-mode noise rejection capabilities.

In conclusion, the INA118U is a precision instrumentation amplifier used for accurate amplification of small differential signals while minimizing common-mode noise interference. Its high accuracy, low offset voltage, and wide input voltage range make it suitable for various applications in fields such as biomedical instrumentation, industrial process control, and data acquisition systems.

기술 솔루션에 INA118U 적용과 관련된 10가지 일반적인 질문과 답변을 나열하세요.

Sure! Here are 10 common questions and answers related to the application of INA118U in technical solutions:

  1. Q: What is the INA118U? A: The INA118U is a precision instrumentation amplifier designed for accurate signal amplification in various technical applications.

  2. Q: What is the input voltage range of the INA118U? A: The INA118U has a wide input voltage range of ±10V, making it suitable for amplifying both small and large signals.

  3. Q: Can the INA118U be used in low-power applications? A: Yes, the INA118U has a low quiescent current of around 700µA, making it suitable for low-power applications.

  4. Q: What is the gain accuracy of the INA118U? A: The INA118U offers high gain accuracy with a typical gain error of only 0.01%.

  5. Q: Is the INA118U suitable for temperature-sensitive applications? A: Yes, the INA118U has a low temperature coefficient of typically 35ppm/°C, ensuring stable performance over a wide temperature range.

  6. Q: Can the INA118U handle differential or single-ended inputs? A: The INA118U can handle both differential and single-ended inputs, providing flexibility in various circuit configurations.

  7. Q: What is the common-mode rejection ratio (CMRR) of the INA118U? A: The INA118U has a high CMRR of typically 100dB, allowing it to reject common-mode noise and interference effectively.

  8. Q: Does the INA118U require external components for operation? A: Yes, the INA118U requires external resistors to set the desired gain and feedback configuration.

  9. Q: Can the INA118U operate with a single power supply? A: Yes, the INA118U can operate with a single power supply, typically ranging from 2.7V to 36V.

  10. Q: What are some typical applications of the INA118U? A: The INA118U is commonly used in medical instrumentation, industrial process control, data acquisition systems, and other precision measurement applications.

Please note that these answers are general and may vary depending on specific datasheet specifications and application requirements.