이미지는 예시일 수 있습니다.
제품 세부사항은 사양을 확인하세요.
INA133U/2K5

INA133U/2K5

Product Overview

  • Category: Integrated Circuit (IC)
  • Use: Instrumentation Amplifier
  • Characteristics: High precision, low noise, high common-mode rejection ratio (CMRR)
  • Package: SOIC-8
  • Essence: The INA133U/2K5 is a precision instrumentation amplifier designed for accurate signal amplification in various applications.
  • Packaging/Quantity: Available in reels of 2500 units.

Specifications

  • Supply Voltage: ±2.25V to ±18V
  • Input Offset Voltage: ±150µV (maximum)
  • Input Bias Current: ±50nA (maximum)
  • Gain Bandwidth Product: 1MHz (typical)
  • Input Common-Mode Voltage Range: -Vs + 1.9V to +Vs - 1.9V
  • Operating Temperature Range: -40°C to +125°C

Pin Configuration

The INA133U/2K5 has the following pin configuration:

___________ V- | 1 8 | V+ IN- | 2 7 | REF IN+ | 3 6 | OUT RG | 4 5 | NC -------------

Functional Features

  • High accuracy and precision amplification of differential signals
  • Excellent common-mode rejection ratio (CMRR) of 100dB (minimum)
  • Low input offset voltage and bias current for improved accuracy
  • Wide input common-mode voltage range for versatile applications
  • Single-supply or dual-supply operation for flexibility

Advantages and Disadvantages

Advantages: - High precision amplification for accurate signal processing - Low noise performance for improved signal integrity - Wide input common-mode voltage range for versatile applications - Flexible supply voltage options

Disadvantages: - Limited gain bandwidth product compared to some other instrumentation amplifiers - Requires external resistors for setting the desired gain

Working Principles

The INA133U/2K5 is based on the principle of an instrumentation amplifier. It consists of a differential amplifier stage followed by a high-gain amplifier. The input signals are amplified differentially, and the common-mode noise is rejected due to the balanced configuration. The gain can be set using external resistors connected to the RG pin.

Detailed Application Field Plans

The INA133U/2K5 finds applications in various fields, including:

  1. Medical equipment: ECG amplification, patient monitoring systems
  2. Industrial automation: Process control, data acquisition systems
  3. Test and measurement: Precision signal amplification, strain gauge amplification
  4. Audio equipment: Microphone preamplifiers, audio signal conditioning

Detailed and Complete Alternative Models

Some alternative models that offer similar functionality to the INA133U/2K5 include:

  1. AD8221: Instrumentation Amplifier with Rail-to-Rail Output
  2. LT1167: Precision Instrumentation Amplifier
  3. MCP6N11: Zero-Drift Instrumentation Amplifier

These alternatives provide comparable performance and can be considered based on specific application requirements.

In conclusion, the INA133U/2K5 is a precision instrumentation amplifier offering high accuracy, low noise, and excellent common-mode rejection. Its wide range of applications and availability of alternative models make it a versatile choice for various signal amplification needs.

기술 솔루션에 INA133U/2K5 적용과 관련된 10가지 일반적인 질문과 답변을 나열하세요.

  1. What is the typical application of INA133U/2K5?
    - The INA133U/2K5 is commonly used as a precision instrumentation amplifier in various technical solutions.

  2. What is the input voltage range of INA133U/2K5?
    - The input voltage range of INA133U/2K5 is typically ±15V.

  3. Can INA133U/2K5 be used for strain gauge measurements?
    - Yes, INA133U/2K5 is suitable for amplifying signals from strain gauges and other bridge sensors.

  4. What is the gain accuracy of INA133U/2K5?
    - The gain accuracy of INA133U/2K5 is typically 0.01%.

  5. Is INA133U/2K5 suitable for low-noise applications?
    - Yes, INA133U/2K5 is designed for low-noise performance, making it suitable for sensitive measurements.

  6. Can INA133U/2K5 operate with a single power supply?
    - Yes, INA133U/2K5 can operate with a single power supply, typically ranging from 2.7V to 36V.

  7. What is the common-mode rejection ratio (CMRR) of INA133U/2K5?
    - The CMRR of INA133U/2K5 is typically 100dB.

  8. Is INA133U/2K5 suitable for industrial control systems?
    - Yes, INA133U/2K5 is commonly used in industrial control systems due to its high precision and reliability.

  9. Can INA133U/2K5 be used in medical instrumentation?
    - Yes, INA133U/2K5 is suitable for medical instrumentation applications requiring precise signal amplification.

  10. What are the typical output voltage swing capabilities of INA133U/2K5?
    - The typical output voltage swing of INA133U/2K5 is ±13V when operating with a ±15V power supply.