이미지는 예시일 수 있습니다.
제품 세부사항은 사양을 확인하세요.
INA141UA/2K5

INA141UA/2K5

Product Overview

Category: Integrated Circuit (IC)

Use: The INA141UA/2K5 is a precision instrumentation amplifier designed for accurate signal amplification in various applications.

Characteristics: - High accuracy - Low noise - Wide bandwidth - High common-mode rejection ratio (CMRR) - Low power consumption

Package: The INA141UA/2K5 is available in a small outline package (SOIC) with 8 pins.

Essence: This IC is essential for amplifying weak signals accurately and reliably in electronic circuits.

Packaging/Quantity: The INA141UA/2K5 is typically sold in reels containing 2500 units.

Specifications

  • Supply Voltage Range: ±2.25V to ±18V
  • Input Offset Voltage: ±150µV (maximum)
  • Input Bias Current: ±50nA (maximum)
  • Gain Bandwidth Product: 1MHz (typical)
  • Common-Mode Rejection Ratio: 86dB (minimum)
  • Operating Temperature Range: -40°C to +85°C

Pin Configuration

The INA141UA/2K5 has the following pin configuration:

```


| | --| V+ | --| IN+ | --| IN- | --| REF | --| OUT | --| V- | --| RG | |___________| ```

Functional Features

  • High input impedance
  • Differential input stage
  • Programmable gain
  • Output voltage swing near the supply rails
  • Internal frequency compensation

Advantages

  • Accurate amplification of weak signals
  • Low noise performance
  • Wide operating temperature range
  • Flexible gain settings
  • Suitable for precision measurement applications

Disadvantages

  • Limited gain bandwidth product compared to some other amplifiers
  • Requires external resistors for gain configuration

Working Principles

The INA141UA/2K5 operates based on the principle of differential amplification. It amplifies the voltage difference between the IN+ and IN- inputs while rejecting common-mode signals. The gain can be adjusted by selecting appropriate resistor values for RG.

Application Field Plans

The INA141UA/2K5 is commonly used in the following applications:

  1. Medical instrumentation
  2. Industrial process control
  3. Data acquisition systems
  4. Strain gauge amplification
  5. Thermocouple amplification

Alternative Models

Some alternative models that offer similar functionality to the INA141UA/2K5 include:

  1. AD620
  2. LT1167
  3. MCP6N11
  4. MAX4208

These alternatives should be evaluated based on specific application requirements and desired performance characteristics.

Word count: 305 words

기술 솔루션에 INA141UA/2K5 적용과 관련된 10가지 일반적인 질문과 답변을 나열하세요.

  1. What is the typical application of INA141UA/2K5?
    - The INA141UA/2K5 is commonly used for precision instrumentation amplification in various technical solutions.

  2. What is the input voltage range of INA141UA/2K5?
    - The input voltage range of INA141UA/2K5 is typically ±VS.

  3. Can INA141UA/2K5 be used in low-side current sensing applications?
    - Yes, INA141UA/2K5 can be used in low-side current sensing applications due to its high common-mode rejection ratio (CMRR).

  4. What is the gain accuracy of INA141UA/2K5?
    - The gain accuracy of INA141UA/2K5 is typically 0.05%.

  5. Is INA141UA/2K5 suitable for battery monitoring systems?
    - Yes, INA141UA/2K5 is suitable for battery monitoring systems due to its high precision and low offset voltage.

  6. Can INA141UA/2K5 operate in single-supply configurations?
    - Yes, INA141UA/2K5 can operate in single-supply configurations with proper biasing.

  7. What is the bandwidth of INA141UA/2K5?
    - The bandwidth of INA141UA/2K5 is typically 500 kHz.

  8. Is INA141UA/2K5 suitable for industrial control and automation applications?
    - Yes, INA141UA/2K5 is suitable for industrial control and automation applications due to its high accuracy and reliability.

  9. Does INA141UA/2K5 have built-in protection features?
    - Yes, INA141UA/2K5 has built-in overvoltage and reverse-voltage protection.

  10. Can INA141UA/2K5 be used in medical instrumentation?
    - Yes, INA141UA/2K5 can be used in medical instrumentation applications requiring precise signal amplification.